Double glazed insulated glass units (IGUs) are engineered assemblies consisting of two or more glass panes separated by a hermetically sealed spacer system, creating an insulating air or gas-filled cavity. This construction provides superior thermal and acoustic performance compared to monolithic glass.
Standard Construction
Glass: 2 panes (3-12mm each)
Spacer: Aluminum/Stainless Steel (6-20mm width)
Sealants: Primary (PIB) + Secondary (Silicone/Polysulfide)
Gas Fill: Argon (90%), Krypton (high-performance), or Air
Advanced Configurations
Triple Glazing: 3 panes + 2 cavities (U-value down to 0.4 W/m²K)
Asymmetrical: Different thicknesses (e.g., 6mm outer + 8mm inner)
Hybrid Units: Combined with Low-E coatings or laminated layers
Center-of-glass values for 4-12-4 configuration
Sound Transmission Class (STC)
4mm/12mm Air/4mm: STC 32
6mm/16mm Argon/6mm: STC 36
Laminated Variant: STC 42+
Frequency-Specific Attenuation
500Hz: 25-35dB reduction
1000Hz: 30-40dB reduction
2000Hz: 35-45dB reduction
Quality Control
Moisture vapor transmission <0.05g/m²/day
Gas retention >90% after 15 years
Sealant adhesion >0.5N/mm²
Certifications
EN 1279 (European IGU standard)
ASTM E2190 (North America)
GB/T 11944 (China)
ISO 20492 (Global performance)
Glazing Systems
Minimum 15mm edge cover
Thermal break framing recommended
Structural silicone bonding options
Environmental Limits
Maximum altitude: 3000m
Temperature range: -40°C to +80°C
Pressure differential: ±3000Pa
Climate Resistance
1000 cycles (-20°C to +60°C)
5000hr humidity exposure (85°C/85%RH)
UV aging per ISO 4892-3
Structural Testing
Wind load resistance (EN 12179)
Water penetration (ASTM E331)
Air infiltration (ASTM E283)
Guardian Glass (ClimaGuard®)
U-value as low as 0.5
25-year performance warranty
Saint-Gobain (SGG ClimaPlus®)
Warm edge spacer systems
PHI-certified options
AGC (EnergyNXT™)
Triple silver Low-E variants
Self-cleaning IGU options
NSG (Pilkington Insulight™)
Krypton-filled units
Acoustic-specific designs
30% recycled glass content
Argon from air separation byproducts
Warm edge spacers reduce edge losses
Contributes to LEED v4.1 credits:
Thermal Performance (EQ)
Daylight Optimization (EQ)
Gas Loss
Cause: Seal failure
Prevention: Dual-seal systems
Condensation
Cause: Desiccant saturation
Prevention: Molecular sieve quality control
Glass Breakage
Cause: Thermal stress
Prevention: Edge deletion for coated glass
Performance Modeling
THERM/WINDOW simulations
Condensation risk analysis
Custom Engineering
Curved IGUs (R>1000mm)
Structural glazing solutions
Quality Verification
Gas concentration testing
Sealant adhesion checks